AU-SM60TL

20-60W/VA Self Monitoring Electronic Transformer

Patented Self Monitoring technology (Pat.No.GB2371424). Fully dimmable with resistive & inductive dimmers. Auto-reset thermal protection. Short circuit and overload protection. 1.0kV SURGE PROTECTION – EN 61547. Suitable for use in commercial or light industrial installations. Loop-in, loop-out primary wiring terminals. No junction box required. Intergrated earth terminals for earth continuity. Pre-wired with 30cm LV cable MR16 lampholder and lamp retaining clip. Safety compliance – EN 61347. EMC compliance – EN 55015, EN 61000, EN 61547. 10 Year guarantee. NOTE: MAX. CABLE LENGTH FROM TRANSFORMER TO THE FURTHEST LAMP IS 2M. MONITORING LED STATUS. ON – Normal operation. OFF – Out of order (check mains power supply). SLOW FLASHING – Short circuit on transformer output. RA.

More

  • Input Voltage (Min): 220 V
  • Input Voltage (Max): 250 V
  • Input Voltage Type: AC
  • Input Voltage Frequency (Min): 30 Hz
  • Input Voltage Frequency (Max): 50 Hz
  • Output Voltage (Min): 12 V
  • Output Voltage (Max): 12 V
  • Output Voltage Type: AC
  • Patented Self Monitoring technology (Pat.No.GB2371424)
  • Fully dimmable with resistive & inductive dimmers
  • Auto-reset thermal protection
  • Short circuit and overload protection
  • 1.0kV SURGE PROTECTION – EN 61547
  • Suitable for use in commercial or light industrial installations
  • Loop-in, loop-out primary wiring terminals
  • No junction box required
  • Intergrated earth terminals for earth continuity
  • Pre-wired with 30cm LV cable MR16 lampholder and lamp retaining clip
  • Safety compliance – EN 61347
  • EMC compliance – EN 55015, EN 61000, EN 61547
  • 10 Year guarantee
  • NOTE: MAX. CABLE LENGTH FROM TRANSFORMER TO THE FURTHEST LAMP IS 2M
  • MONITORING LED STATUS
  • ON – Normal operation
  • OFF – Out of order (check mains power supply)
  • SLOW FLASHING – Short circuit on transformer output
  • RAPID FLASHING – Overload condition on transformer output
Spec Sheet

    SKU Code
    AU-SM60TL

    Join Our Mailing List

    The latest news & special offers, right to your inbox!

    Don't worry. We know you value your privacy, which is exactly why we won’t share your information with anyone else.

    Connect Across the Web

    Connect & Share:

    View Photos & Videos:

    Browse Catalogues:

    Registered UK Address: Aurora Ltd | 16 Alban Park | Hatfield Road | St. Albans | AL4 0JJ | England

    TEL: +44 (0) 1727 83 66 11 | FAX: +44 (0) 1727 83 66 22

    © 1999 - 2016 auroralighting.com

    France

    Select Location & Language

    Aurora Lighting is a global organization serving markets around the world. Please select your region, or click below to visit our Global site to view our 2,500 products: